چکیده مقاله
In this paper, a new procedure for dynamic calibration of Drop Weight Impact Testers DWIT is developed The DWIT is calibrated by measuring velocities before and after rebounding and using impulse balance equation By performing a stage of numerical integration, linear dynamic calibration factor can be extracted This procedure is very simple, and can be performed during tests No additional accessories and equipments are needed during execution of the procedure More over, different calibration methods are reviewed here Controlling and decreasing of errors and related sources have been developed in this procedure
کلیدواژهها
نویسندگان
شیوه ارجاع
Fakhar N., M and Shokrieh, M.M,1386,A New Procedure for Dynamic Calibration of Drop Weight Impact Testers,02nd Tehran International Congress on Manufacturing Engineering (TICME2007),Tehran