چکیده مقاله
In this paper evaluation of seismic capacity of a historical building is carried out It had been used as a national library about 40 years ago Also, before that, it had been constructed as a part of a Royal complex This building has been constructed by traditional methods using bricks and mortars The ceilings system of the structure consists of jack arches Also, the roof of the building has been constructed with wood trusses The building does not have any designed lateral bearing system Lateral resistant of the building is due to masonry walls and due to brittle and non ductile performance of it In secondary cycles of earthquake vibration, it will loose its stiffness and strengthening radically Also the building does not have any reliable about integrity Load bearing systems are not reliable too In this paper the evaluation of resistant capacity of the building is established and the weak points of the system are distinguished For some masonry columns some traditional method of steel jacketing is designed and for increasing the reliability of the columns, FRP sheets are applied In order to retrofits the walls, FRP sheets are installed on its surfaces, the externally bonded FRP sheets are strengthening the wall against in plane and out of plane applied horizontal forces Combination of the steel jacketing and externally bonded FRP sheets is prescribed to achieve an integrated system of the elements
کلیدواژهها
نویسندگان
شیوه ارجاع
Rezaifar, Omid and Gholhaki, Majid and Hemmati, S.,1388,Seismic retrofit of a historical building in Tehran university museum using FRP technology and steel jacketing,8th International Congress on Civil Engineering,Shiraz