چکیده مقاله
Previous studies show there are differences between experimental responses of bolted flange joint steel frames and those of the analytical models In most of the cases these differences result from some geometrical or mechanical uncertainties, and in this specific structure, complex behavior of joints is one of these uncertainties Therefore, knowing the real dynamic characteristics of this structure can help to predict its behavior under different conditions In this article, a three story steel frame with bolted flange joints and one bay in each direction was constructed Then, dynamic impact testing with hammer was utilized in most of the nodes of the structure and by using a spectrum analyzer the frequency response functions FRFs were obtained Furthermore, by the use of experimental modal analysis of measured FRFs, the natural frequencies of the structure were identified and compared with those of the analytical models of the structure
کلیدواژهها
نویسندگان
شیوه ارجاع
Davoodi, Mohammad Reza and Mahdavi, Maziar and Mostafavian, Amin,1391,Dynamic Identification of a Three Story Steel Frame with Bolted Flange Joints,9th International Congress on Civil Engineering,Isfahan
ارائهشده در
مجموعه مقالات نهمین کنگره بین الملی مهندسی عمران19 اردیبهشت 1391 · اصفهان